CALIBRATION, RENTAL,TESTING, SALES AND SERVICE




Zone 1 DNV certified Hydraulic Flushing Unit
Specifications:
Flushing rig capable of flushing at pressures of up to 207 bar (3000 psi) using all offshore
production type water glycols (eg: HW443, HW540, Castro; Transaqua) and mineral oil.
Fluid compatibility: Mineral & synthetic oils, production fluids
Electric motor: 22kW, 415 volt 3ph 50Hz
Cooler motor: 0.37kW
Heater: 2kW
Max Pressure: 207 bar (continuous) 3000 psi
Maximum Flow: 90ltrs/min
Outlet connection: 1” BSP female
Return Connection: 1” BSP female
Reservoir capacity: 230 litres (50 gallons) c/w with the following equipment:
a) filter /breather
b) sight glass x 3
c) low level switch
d) 2kW heater
e) 3 micron hydac duplex return line filter
f) Magnetic drain plug
g) Pump vent line c/w diffuser
h) 1” drain ball valve
Pump inlet selector valve
100 micron hydac inlet filter
Fully adjustable pressure regulating valve, panel mounted
Pressure regulating outlet check valve
Mahle high pressure carbon steel filter suitable for use with all above fluids & c/w with a 3
micron element, bypass valve and a visual clogging indicator.
Flow control valve panel mounted
4” dia, 400 bar/ 5000 psi dual scale vibration damped pressure gauge with 1% accuracy
High pressure isolating ball valve
¼” NPT (F) nitrogen injection inlet bulkhead connector on panel
Return line isolating ball valve
UCC inline flow meter panel mounted
Sampling point c/w a needle type isolation valve panel mounted
Electrically driven (0.37kW) air blast oil cooler
All associated electrical controls suitable for use in a hazardous area
Dimensions: 1700mm x 1050mm x 1735mm
Approx Weight (Dry): 1025 Kgs (incl slings)








Click on image to enlarge
-